Reference Guide
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC
CMC
PST0128
Message No memory is detected.
Detailed
Description
System BIOS was unable to detect memory in the system . This exception occurred
early in system power on, thus the system may not display video (BIOS Post
Exception 80).
Recommended
Response
Action
Inspect System Memory.
Category System Health (PST = BIOS POST)
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message No memory is detected. Inspect memory devices
Filter
Visibility
IPMI
Alert
SNMP
Alert
Email
Alert
Remote System
Log
WS
Eventing
iDRAC ✔ ✔ ✔ ✔ ✔
CMC
LC Log LCD OS Log Power
Off
Power
Cycle
Reset Chassis Event
Proxy
iDRAC ✔* ✔
CMC
PST0129
Message Memory is detected, but is not configurable.
Detailed
Description
System BIOS detected memory, but was unable to configure the memory for
system operation. Compare system memory installation to supported system
memory configurations. Reduce the system to minimum memory configuration if
acceptable. This exception occurred early in system power on, thus the system
may not display video.(BIOS POST Exception Code 81).
Recommended
Response
Action
Compare system memory installation to supported system memory configurations.
Category System Health (PST = BIOS POST)
1041