Reference Guide

If the file backup fails, try to restore the failed file from a previous backup.
When the backup with the Verify option is complete without any errors, delete
the Virtual Disk.
Recreate a new Virtual Disk with new drives.
Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2082
Description Virtual disk rebuild failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: A physical disk included in the virtual disk has failed or is not functioning. A
user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has
failed by locating the disk that has a red X for its status. Restart the virtual disk
rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID — 2083
Description Physical disk rebuild failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: A physical disk included in the virtual disk has failed or is not functioning. A
user may also have cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has
failed by locating the disk that has a red X for its status. Rebuild the virtual disk
rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
72