Reference Guide
hardware. Make sure that the cables are attached securely. See the hardware
documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095,
2129, 2201, 2203, 2270, 2282, 2369
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2347
Description The rebuild failed due to errors on the source physical disk.
Severity Critical / Failure / Error
Cause and
Action
Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
• Perform a backup with the Verify option.
• If the file backup fails, try to restore the failed file from a previous backup.
• When the backup with the Verify option is complete without any errors, delete
the Virtual Disk.
• Recreate a new Virtual Disk with new drives.
• Restore the data from backup.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2348
Description The rebuild failed due to errors on the target physical disk.
Severity Critical / Failure / Error
Cause and
Action
Cause:You are attempting to rebuild data on a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after
replacing the disk, initiate the Rebuild task. You may need to assign the new disk as
a hot spare to initiate the rebuild.
170