Reference Guide
SNMP Trap
Numbers
1001
Event ID — 2326
Description A foreign configuration has been detected.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes. The controller has physical disks
that were moved from another controller. These physical disks contain virtual disks
that were created on the other controller. See the Import Foreign Configuration
and Clear Foreign Configuration section in the Server Administrator Storage
Management User’s Guide for more information.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751
Event ID — 2327
Description The NVRAM has corrupted data. The controller is reinitializing the NVRAM.
Severity Warning / Non-critical
Cause and
Action
Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may
occur after a power surge, a battery failure, or for other reasons. The controller is
reinitializing the NVRAM. The controller properties reset to the default settings after
the reinitialization is complete.
NOTE: The controller is taking the required corrective action. If this alert is
generated often (such as during each reboot), replace the controller.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2266
Local Response Agent (LRA) Number: 2060
SNMP Trap
Numbers
753
Event ID — 2328
Description The NVRAM has corrupt data.
Severity Warning / Non-critical
162