Reference Guide
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751, 851, 951
Event ID — 2297
Description An EMM has been removed.
Severity Critical / Failure / Error
Cause and
Action
Cause: An EMM has been removed.
Action: Reinsert the EMM. See the hardware documentation for information on
replacing the EMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854, 954
Event ID — 2298
Description The enclosure has a bad sensor %1.
Severity Warning / Non-critical
Cause and
Action
Cause: The enclosure has a bad sensor. The enclosure sensors monitor the fan
speeds, temperature probes, and so on. The % indicates a substitution variable. The
text for this substitution variable is displayed with the alerts in the alert log and can
vary depending on the situation.
Action: See the hardware documentation for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
151