Reference Guide
SNMP Trap
Numbers
1201
Event ID — 2281
Description Virtual disk has inconsistent data.
Severity OK / Normal / Informational
Cause and
Action
Cause: The virtual disk has inconsistent data. This may be caused when a power
loss or system shutdown occurs while data is being written to the virtual disk. This
alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2127
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID — 2282
Description Hot spare SMART polling failed.
Severity Critical / Failure / Error
Cause and
Action
Cause: The controller firmware attempted a SMART polling on the hot spare but
was unable to complete it. The controller has lost communication with the hot
spare.
Action: Check the health of the disk assigned as a hot spare. You may need to
replace the disk and reassign the hot spare. Make sure the cables are attached
securely. See the Server Administrator Storage Management User’s Guide, for more
information on checking the cables.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2283
Description A redundant path is broken.
Severity Warning / Non-critical
145