Reference Guide
Cause and
Action
Cause: The physical disk may not have a supported version of the firmware or the
disk may not be supported by your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the
disk is not supported by your service provider, replace the disk with one that is
supported.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID — 2212
Description The controller battery temperature is above normal.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2213
Description Recharge count maximum exceeded.
Severity Warning / Non-critical
Cause and
Action
Cause: The battery has been recharged more times than the battery recharge limit
allows.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
120