1151
Event ID — 2178
Description The controller battery Learn cycle has timed out.
Severity Warning / Non-critical
Cause and
Action
Cause: The controller battery must be fully charged before the Learn cycle can
begin. The battery may be unable to maintain a full charge causing the Learn cycle
to timeout. Additionally, the battery must be able to maintain cached data for a
specified period of time in the event of a power loss. For example, some batteries
maintain cached data for 24 hours. If the battery is unable to maintain cached data
for the required period of time, then the Learn cycle timeout occurs.
Action: Replace the battery pack as the battery is unable to maintain a full charge.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2179
Description The controller battery Learn cycle has been postponed.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None