Reference Guide

Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PST0192
Message Shut-down test failed.
Detailed
Description
System BIOS shutdown test failed during POST. This exception occurred early in
system power on, thus the system may not display video. (BIOS POST exception
code C0).
Recommended
Response
Action
Check system event log for CMOS battery exceptions. Remove and reapply input
power. If the problem persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
Subcategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message Shut-down test failed. Power cycle system
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PST0193
Message BIOS POST memory test failed.
Detailed
Description
System BIOS POST memory test failed. This exception occurred early in system
power on, thus the system may not display video. (BIOS POST exception code C1)
Recommended
Response
Action
Compare system memory installation to supported system memory configurations.
Reduce system configuration to minimum memory configuration.
Category System Health
Subcategory PST = BIOS POST
Severity Severity 1 (Critical)
997