Reference Guide

PST0129
Message Memory is detected, but is not configurable.
Detailed
Description
System BIOS detected memory, but was unable to configure the memory for
system operation. Compare system memory installation to supported system
memory configurations. Reduce the system to minimum memory configuration if
acceptable. This exception occurred early in system power on, thus the system
may not display video.(BIOS POST Exception Code 81).
Recommended
Response
Action
Compare system memory installation to supported system memory configurations.
Category System Health
Subcategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message Memory is detected, but is not configurable. Check memory devices
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PST0130
Message Memory is configured, but not usable.
Detailed
Description
During memory configuration system BIOS encountered device failures or speed
configurations that resulted in unused memory. This exception occurred early in
system power on, thus the system may not display video. (BIOS POST Exception
code 82)
Recommended
Response
Action
Remove input power. Reseat memory devices or reduce system to minimum
supported memory configuration.
Category System Health
Subcategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID 2425
LCD Message Memory is configured, but not usable. Check memory devices
988