Reference Guide
PDR60
Message Error occurred on arg1 : arg2 .
Arguments
• arg1 = physical disk
• arg2 = error code
Detailed
Description
The reason for the error can vary depending on the situation. The firmware error
code is indicated in the message.
Recommended
Response
Action
Verify the health of attached devices. Review the Lifecycle log for significant
events. Replace faulty hardware, if required. Make sure the cables are attached
securely. Refer to the storage hardware documentation for more information on
checking the cable connections.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2346
Server
Administrator
Trap ID
90300
PDR61
Message The rebuild of arg1 failed due to errors on the source physical disk.
Arguments
• arg1 = physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
Recommended
Response
Action
Replace the source disk and restore data from backup.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 1 (Critical)
920