Reference Guide

Detailed
Description
The controller firmware attempted to do SMART polling on the hot spare but could
not complete the SMART polling. The controller may have lost communication
with the hot spare.
Recommended
Response
Action
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign
the hot spare. Make sure the cables are attached securely. See the storage
hardware documentation for more information on checking the cables.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2282
Server
Administrator
Trap ID
90400
PDR52
Message A redundant path is broken.
Detailed
Description
The controller has two connectors that are connected to the same enclosure. The
communication path on one connector has lost connection with the enclosure.
The communication path on the other connector is reporting this loss.
Recommended
Response
Action
Make sure the cables are attached securely. See the Cables Attached Correctly
section for more information on checking the cables. Make sure both Enclosure
Management Modules (EMMs) are healthy.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2283
914