Reference Guide
PDR36
Message The only hot spare available is a SAS disk arg1 .
Arguments
• arg1 = PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SAS
technology. The physical disks in the virtual disk are using SATA technology.
Because of this difference in technology, the hot spare cannot rebuild data if one
of the physical disks in the virtual disk fails.
Recommended
Response
Action
Add a SATA disk that is large enough to be used as the hot spare and assign the
new disk as a hot spare.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2207
Server
Administrator
Trap ID
90300
PDR37
Message The arg1 is not supported.
Arguments
• arg1 = physical device
Detailed
Description
The physical device may not have a supported version of the firmware or the
physical device may not be supported.
Recommended
Response
Action
If the physical device is supported, then update the firmware to a supported
version. If the physical device is not supported, then replace the physical device
with one that is supported.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
904