Reference Guide
Server
Administrator
Event ID
2109
Server
Administrator
Trap ID
90300
PDR23
Message SMART warning degraded for arg1
Arguments
• arg1 = PD Name
Detailed
Description
A disk is degraded and has received a SMART alert (predictive failure). The disk is
likely to fail in the near future.
Recommended
Response
Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2110
Server
Administrator
Trap ID
90300
PDR24
Message Failure prediction threshold exceeded on arg1 due to test. No action needed.
Arguments
• arg1 = PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure) due to test conditions.
895