Reference Guide

Recommended
Response
Action
Retry the Replace Member Disk operation with a different target physical disk. If the
problem persists, check the condition of the target physical disk and replace if
necessary, then rety the operation.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
2183
Server
Administrator
Trap ID
90400
PDR22
Message SMART warning temperature for arg1
Arguments
arg1 = PD Name
Detailed
Description
A disk has reached an unacceptable temperature and received a SMART alert
(predictive failure). The disk is likely to fail in the near future.
Recommended
Response
Action
Do the following: 1) Determine why the physical disk reached an unacceptable
temperature. For example, a fan failure, incorrect thermostat settings, or the room
temperature may be too hot or cold. 2) Verify that the fans in the server or
enclosure are working. 3) If the physical disk is in an enclosure, check the
thermostat settings and examine whether the enclosure is located near a heat
source. Verify the enclosure has enough ventilation and that the room temperature
is not too hot. Refer to the enclosure documentation for more diagnostic
information. 4) If you cannot identify why the disk has reached an unacceptable
temperature, then replace the disk. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a
physical disk that is included in a non-redundant virtual disk causes the virtual disk
to fail and may cause data loss.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
894