Reference Guide

Initial Default None
Server
Administrator
Event ID
2399
Server
Administrator
Trap ID
90100
PDR21
Message SMART warning for arg1
Arguments
arg1 = PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the
near future.
Recommended
Response
Action
Replace the disk that has received the SMART alert. If the physical disk is a member
of a non-redundant virtual disk, then back up the data before replacing the disk.
Removing a physical disk that is included in a non-redundant virtual disk will cause
the virtual disk to fail and may cause data loss.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2108
Server
Administrator
Trap ID
90300
PDR210
Message Successfully updated configuration data on the arg1 .
Arguments
arg1 = physical disk name
Detailed
Description
This event is generated while initializing the drives during reboot. The controller
updated the configuration data on the physical disks identified in the message. The
drive configuration was updated because the following conditions were present: 1)
The spundown drives were used for configuration. Spundown drives are drives that
890