Reference Guide

Server
Administrator
Event ID
2441
Server
Administrator
Trap ID
90400
PDR105
Message arg1 is assigned as dedicated hot-spare.
Arguments
arg1 = physical disk
Detailed
Description
The physical disk drive identified in the message is assigned as a dedicated hot-
spare.
Recommended
Response
Action
No response action is required.
Category Storage
Subcategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PDR106
Message arg1 is unassigned as dedicated hot-spare.
Arguments
arg1 = physical disk
Detailed
Description
A physical disk identified in hte hot-spare that was assigned as a hot spare has been
un-assigned and is no longer functioning as a hot spare. The physical disk was
unassigned by a user or automatically by the storage management software. When
one of the disk in a virtual disk fails, data is rebuilt onto the hot spare, The hot spare
becomes a member of the virtual disk and is no longer assigned as a hot spare. In
864