Reference Guide
Detailed
Description
A low-severity issue is detected in the component identified in the message.
Recommended
Response
Action
Remove and reinsert the component identified in the message, and then monitor
the log for a re-occurrance of the issue. If the issue persists, and occurs during
server startup, update the component firmware. If the issue persists and occurs
during OS runtime, restart the server and update the OS drivers for the component
identified in the message.
Category System Health
Subcategory PCI = PCI Device
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
848