Reference Guide
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID 2419
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
PCI3018
Message New PCI card(s) have been detected in the system. Fan speeds may have changed
to add additional cooling to the cards.
Detailed
Description
New PCI card(s) have been detected in the system that may require additional
airflow. Fan speeds may have changed to add additional cooling to the cards.
Recommended
Response
Action
Changing default fan response to PCIe cards should be done with appropriate
understanding of the PCIe cooling needs of the cards present in the system. If the
automatic cooling response is insufficient, additional cooling can be added by one
of the following methods. 1) From iDRAC Web GUI, click Hardware -> Fans ->
Setup, then from the fan speed offset drop-down list appropriately select the
cooling level needed or set the minimum fan speed to a custom value. 2) From F2
System Setup, select iDRAC Settings -> Thermal, and set a higher fan speed from
the fan speed offset or minimum fan speed. 3) For RACADM commands run
"racadm help system.thermalsettings". If a lower fan speed is required, contact your
service provider for the appropriate IPMI commands to reduce the default fan
speed response for new PCIe cards.
Category System Health
Subcategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID 2419
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;LC Log;Remote System Log;None
846