Reference Guide
MEM6005
Message Memory device has failed. Memory device location: arg1 , Possible memory
module event cause: arg2 .
Arguments
• arg1 = location
• arg2 = cause
Detailed
Description
The memory module failed because of an irrecoverable error.
Recommended
Response
Action
Review the Embedded System Management (ESM) Log for memory exceptions.
Remove the old memory module and install a new memory module at the
identified location .
Category System Health
Subcategory MEM = Memory
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5405
Server
Administrator
Trap ID
5405
MEM7000
Message The memory riser mismatch was corrected.
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID 2267
LCD Message No LCD message display defined.
Initial Default LC Log