Reference Guide
Initial Default SNMP Alert;EMAIL Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
IOID111
Message Unable to configure the virtual address of NIC arg1 Port arg2 .
Arguments
• arg1 = controller
• arg2 = port
Detailed
Description
The virtual address of the NIC port identified in the message could not be
successfully configured because either the network port connection is not enabled
or the NIC is not capable of Virtual Addressing.
Recommended
Response
Action
Verify that the network port is enabled and that the port has Virtual Addressing
capability and then retry the operation.
Category Configuration
Subcategory IOID = IO Identity Optimization
Severity Severity 2 (Warning)
Trap/EventID 10770
LCD Message No LCD message display defined.
Initial Default SNMP Alert;EMAIL Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
IOID112
Message The initiator properties of the NIC arg1 Port arg2 are successfully configured.
Arguments
• arg1 = Controller
• arg2 = Port
588