Reference Guide

LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
HWC3006
Message Unable to QuickDeploy server in slot arg1 .
Arguments
arg1 = slot number
Detailed
Description
There are not enough IPv4 addresses reserved for the servers in this chassis.
Therefore the newly inserted server could not be configured with the QuickDeploy
feature.
Recommended
Response
Action
Do the following: 1) Check the number of reserved IPv4 addresses for
QuickDeploy. 2) Modify it such that the newly inserted blade will obtain an IP
address for QuickDeploy. 3) Reseat the server to see the QuickDeploy prompt on
LCD panel or manually configure the network parameters for the server.
Category System Health
Subcategory HWC = Hardware Config
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
HWC4000
Message A hardware incompatibility detected between BMC/iDRAC firmware and CPU.
Detailed
Description
A hardware incompatibility was detected between BMC/iDRAC firmware and
Processor(s). An iDRAC or BMC firmware update is needed.
550