Reference Guide
FC017
Message Unable to perform the operation due to an internal error in iDRAC.
Detailed
Description
An internal error occurred in iDRAC and the operation cannot continue. An iDRAC
reset is required to recover from the error.
Recommended
Response
Action
Disconnect the AC power source from the system, reconnect the power source,
and retry the operation.
Category Configuration
Subcategory FC = Fiber Channel
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
FC102
Message The FC arg1 port arg2 link is not functioning either because the FC cable is not
connected or the FC device is not functioning.
Arguments
• arg1 = controller ID
• arg2 = port ID
Detailed
Description
The FC controller port link identified in the message is not functioning either
because the FC cable is not connected or the FC device is not functioning.
Recommended
Response
Action
Do the following: 1) Make sure that the FC port is enabled. 2) Make sure the
Activity/Speed LEDs are lit if the physical port has LEDs. 3) Check the FC cable and
FC cable connections for proper installation. 4) Check that the attached FC switch
is functioning.
Category System Health
Subcategory FC = Fiber Channel
Severity Severity 2 (Warning)
Trap/EventID 2538
LCD Message No LCD message display defined.
490