Reference Guide
Subcategory FAN = Fan Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
FAN8503
Message Chassis was turned off because more than two internal fans stopped functioning
properly.
Detailed
Description
The Chassis was turned off because more than two Chassis internal fans stopped
functioning properly. The fans with problems are identified in the CMC Hardware
(System Event Log) and Chassis Logs.
Recommended
Response
Action
Check whether or not the Chassis internal fans are functioning properly. Using the
CMC RACADM utility, type the following command to identify fans that are not
functioning properly, "racadm getsel". Using the CMC Web UI, select the chassis
and the then Logs tab and then select Hardware Log. Reinsert or replace fans that
are not functioning properly.
Category Audit
Subcategory FAN = Fan Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
FAN900
Message The Enhanced Cooling Mode is successfully enabled.
Detailed
Description
The Enhanced Cooling Mode is successfully enabled.
474