Reference Guide
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5104
Server
Administrator
Trap ID
5104
FAN0027
Message The arg1 sensor has failed with a value of arg2 RPM.
Arguments
• arg1 = sensor name
• arg2 = fan speed
Detailed
Description
The sensor identified in the message has failed. The sensor may be required for
optimal system performance.
Recommended
Response
Action
Check the Embedded System Management (ESM) Log for any sensor related
faults.If the fan sensor has failed, replace the system board. For more information,
contact your service provider.
Category System Health
Subcategory FAN = Fan Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5105
Server
Administrator
Trap ID
5105
FAN1000
Message arg1 was removed.
Arguments
• arg1 = Fan Sensor Name
Detailed
Description
The enclosure detected that a fan was removed and the enclosure is no longer
functioning in optimal condition..
470