Reference Guide
FAN0025
Message The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
Arguments
• arg1 = sensor name
• arg2 = fan speed
Detailed
Description
The fan identified in the message is not functioning correctly. The fan may be
installed incorrectly or may be failing.
Recommended
Response
Action
Remove and re-install the fan, or replace the fan. If the issue persists, contact your
service provider.
Category System Health
Subcategory FAN = Fan Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5103
Server
Administrator
Trap ID
5103
FAN0026
Message The arg1 sensor detected an error with a value of arg2 RPM.
Arguments
• arg1 = sensor name
• arg2 = fan speed
Detailed
Description
The fan sensor identified in the message indicates that the related fan has
exceeded critical RPM thresholds..
Recommended
Response
Action
Remove and re-install the fan, or replace the fan with a new fan. If the issue
persists, contact your service provider.
Category System Health
Subcategory FAN = Fan Event
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
469