Reference Guide

Recommended
Response
Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the
system to check if the fan is working properly, 2) Replace the system board if the
fan sensor has failed. 3) If the issue persists, contact your service provider.
Category System Health
Subcategory FAN = Fan Event
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default OS Log;None
Server
Administrator
Event ID
5101
Server
Administrator
Trap ID
Not Applicable
FAN0024
Message The arg1 sensor returned to a normal state with a value of arg2 RPM.
Arguments
arg1 = sensor name
arg2 = fan speed
Detailed
Description
The sensor identified in the message has returned to a normal state.
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory FAN = Fan Event
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5102
Server
Administrator
Trap ID
5102
468