Reference Guide

Detailed
Description
The firmware on the EMM modules is not the same version. It is required that both
modules have the same version of the firmware. This alert may be caused when
you attempt to insert an EMM module that has a different firmware version than an
existing module.
Recommended
Response
Action
Download the same version of the firmware to both EMM modules.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID 4338
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2120
Server
Administrator
Trap ID
85300
ENC40
Message A new enclosure was detected on arg1 .
Arguments
arg1 = controller name
Detailed
Description
The controller detected a new enclosure. This is due either to a hot plug of an
enclosure, or a power state change of an enclosure. In addition, this message is
generated if the daisy chain order of the enclosures changes.
Recommended
Response
Action
No response action is required.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default LC Log
449