Reference Guide

ENC31
Message Firmware download on arg1 has failed.
Arguments
arg1 = Enclosure Name
Detailed
Description
The system was unable to download firmware to the enclosure. The controller may
have lost communication with the enclosure. There may have been problems with
the data transfer or the download media may be corrupt.
Recommended
Response
Action
Attempt to download the enclosure firmware again. If problems continue, verify
that the controller can communicate with the enclosure. Make sure that the
enclosure is powered ON. Refer to the storage hardware documentation for
information on checking the cables.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID 4338
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2355
Server
Administrator
Trap ID
85300
ENC32
Message Storage Enclosure Processor (SEP) for arg1 has been rebooted.
Arguments
arg1 = Enclosure Name
Detailed
Description
The SEP has been rebooted as part of the firmware download operation and will be
unavailable until the operation completes.
Recommended
Response
Action
No response action is required.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
447