Reference Guide

Recommended
Response
Action
No response action is required.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2303
Server
Administrator
Trap ID
85100
ENC28
Message Enclosure Management Module (EMM) firmware version mismatch detected in
arg1 . arg2 arg3 .
Arguments
arg1 = enclosure name
arg2 = EMM 0 version
arg3 = EMM 1 version
Detailed
Description
The firmware on the EMM modules is not the same version. Both modules must
have the same firmware version. This message is caused when you attempt to
insert an EMM module that has a different firmware version than an existing
module.
Recommended
Response
Action
Upgrade to the same version of the firmware on both EMM modules.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 2 (Warning)
Trap/EventID 4338
LCD Message No LCD message display defined.
Initial Default LC Log
444