Reference Guide
Server
Administrator
Event ID
2301
Server
Administrator
Trap ID
85400
ENC26
Message arg1 is not responding.
Arguments
• arg1 = enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state. It is not
responding to storage management commands or there is a connectivity problem
between the controller and enclosure.
Recommended
Response
Action
Verify the health of the enclosure and its components. See the hardware
documentation to for more information. Contact technical support.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2302
Server
Administrator
Trap ID
85400
ENC27
Message SAS or SATA mixing of physical disks is not supported within the arg1 .
Arguments
• arg1 = Enclosure Name
Detailed
Description
The enclosure cannot support both SAS and SATA physical disks. Physical disks
may be disabled. This alert is provided for informational purposes.
443