Reference Guide

Detailed
Description
An Enclosure Management Module (EMM) has failed. The failure may be caused by
a loss of power to the EMM. The EMM self-test may also have identified a failure.
There may also be a firmware problem or a multi-bit error.
Recommended
Response
Action
Reseat the Enclosure Management Module (EMM). See the storage hardware
documentation for information on replacing the EMM. Replace the EMM. Contact
technical support if the issue persists.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2293
Server
Administrator
Trap ID
85400
ENC2
Message arg1 was removed..
Arguments
arg1 = Enclosure Management Module Name
Detailed
Description
An Enclosure Management Module (EMM) was removed.
Recommended
Response
Action
Reinsert the Enclosure Management Module (EMM). See the storage hardware
documentation for information on replacing the EMM.
Category Storage
Subcategory ENC = Storage Enclosr
Severity Severity 1 (Critical)
Trap/EventID 4337
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
2297
439