Reference Guide

Detailed
Description
A PCI adapter was detected as present but it does not respond to PCI
Configuration Space access, so is very sick or not inserted sungly in the PCI
physical slot connector
Recommended
Response
Action
Reseat or replace PCI adapter in the PCI slot indicated
Category System Health
Subcategory DIAG = Diagnostic
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG8611
Message User reported not hearing speaker tone
Detailed
Description
Recommended
Response
Action
If the beep was not heard, verify the internal speakers are connected properly. On
some systems, internal speakers are a purchased option. For a given system, if the
speaker is optional, it might not exist on that system. If audio is not heard, make
sure to unplug anything plugged into an external headphone jack and rerun the
test. External HP jacks can mute the internal speakers at the hardware level.
Category System Health
Subcategory DIAG = Diagnostic
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
409