Reference Guide

Server
Administrator
Trap ID
Not Applicable
DIAG8158
Message arg1 Drive arg2 - S/N arg3 , incorrect status = arg4 \n arg5 .
Arguments
arg1 = Backplane|Expander|RD1000
arg2 = Drive Location
arg3 = Serial Number
arg4 = 80000000000000??
arg5 = Error Reason
Detailed
Description
A device failed a command and testing cannot complete.
Recommended
Response
Action
Retry test. If failure persists and BIOS is up to date, a hardware problem is indicated.
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG8160
Message PERC Battery arg1 - incorrect status = arg2 \n arg3 .
Arguments
arg1 = PERC Controller Location
arg2 = 80000000000000??
arg3 = Error Reason
Detailed
Description
406