Reference Guide
DIAG0314
Message Thermal: The ( arg1 ) reading ( arg2 C) exceeds the thermal limit.
Arguments
• arg1 = Sensor Name
• arg2 = Degrees
Detailed
Description
Recommended
Response
Action
Check the event log for thermal events, including defective fans and defective
sensors. Inspect the system for clogged or obstructed air vents. Make sure that the
BIOS is current and rerun the diagnostics.
Category System Health
Subcategory DIAG = Diagnostic
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG0315
Message Sensor: The ( arg1 ) reading arg2 C) is lower than expected.
Arguments
• arg1 = Sensor Name
• arg2 = Degrees
Detailed
Description
Recommended
Response
Action
Check the event log for thermal events, including defective fans and defective
sensors. Inspect the system for clogged or obstructed air vents. Make sure that the
BIOS is current and rerun the diagnostics.
Category System Health
Subcategory DIAG = Diagnostic
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
376