Reference Guide

LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG0150
Message Hard Drive - No Hard Drive detected, or disk controller not supported.
Detailed
Description
Recommended
Response
Action
Hard drives on desktops should be found if connected to the chipset disk
controller but PERC/SCU/SAS Adapters are not supported by legacy ePSA so if the
hard drive is connected to these controllers this message is just a warning. If the
system has a hard disk connected to the System Board chipset disk controller,
power down the system and check the signal and power connections to it. Rerun
the diagnostic.If no error occurs then it was a cable or connector issue.
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG0151
Message Hard Drive arg1 - S/N arg2 , incorrect status = arg3 \n arg4 .
Arguments
arg1 = Drive Location
arg2 = Serial Number
arg3 = 80000000000000??
arg4 = Error Reason
365