Reference Guide
Detailed
Description
Prior failure checking removed, is now obsolete.
Recommended
Response
Action
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG0147
Message Optical Drive arg1 - Self test: arg2 .
Arguments
• arg1 = Nth Drive
• arg2 = Error Reason
Detailed
Description
Recommended
Response
Action
This typically is a user error since these drives can be disconnected from the
system. If disconnected, reconnect the optical drive to system board. Check BIOS
setup to make sure the SATA port the drive is connected and has not been
disabled. Rerun the diagnostic. If errors persist the optical drive is defective.
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
363