Reference Guide
Recommended
Response
Action
Hard drives are not required on all systems so this message is usually a warning.
Desktops and Servers: If the system has a hard disk, power down system and check
the signal and power connections to it. Rerun the diagnostic.If no error occurs
then it was a cable or connector issue.
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
DIAG0142
Message Hard Drive arg1 - S/N arg2 , arg3 self test unsuccessful arg4 .
Arguments
• arg1 = Drive Location
• arg2 = Serial Number
• arg3 = DST Short, DST Long
• arg4 = Error Reason
Detailed
Description
Recommended
Response
Action
If <Error Reason> is "terminated" then the disk controller terminated the test so a
retry of the test is advisable.Otherwise the hard drive should be replaced. {In the
factory, this test type may also be DEFT, in addition to DST Short and DST Long.
The "terminated" case should not occur in the field, only in development due to
software issues}
Category Storage
Subcategory DIAG = Diagnostic
Severity Severity 2 (Warning)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
Not Applicable
360