Reference Guide

CTL214
Message The Local Key Management (LKM) encryption key in the arg1 has changed.
Arguments
arg1 = controller name
Detailed
Description
The Local Key Management (LKM) encryption key in the controller identified in the
message has changed.
Recommended
Response
Action
No response action is required.
Category Storage
Subcategory CTL = Storage Contr
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default None
Server
Administrator
Event ID
2411
Server
Administrator
Trap ID
75100
CTL215
Message Redundant path disconnected on arg1 .
Arguments
arg1 = Controller Name
Detailed
Description
The controller identified in the message has two connectors that are connected to
the same enclosure. The communication path on one connector has lost
connection with the enclosure. The communication path on the other connector
is reporting this loss.
Recommended
Response
Action
Make sure both the cables are securely attached to the enclosure and controller.
FOr more information about connecting the cables to the enclosure, see the
Cables Attached Correctly section in the PERC Users Guide. Also, make sure both
Enclosure Management Modules (EMMs) are healthy.
Category Storage
Subcategory CTL = Storage Contr
Severity Severity 2 (Warning)
301