Reference Guide
Server
Administrator
Trap ID
Not Applicable
CPU0801
Message CPU arg1 voltage regulator module failed.
Arguments
• arg1 = number
Detailed
Description
System performance may be degraded or the system may fail to operate.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
Subcategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> voltage regulator module failed. Reseat module
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
CPU0802
Message A predictive failure detected on CPU arg1 voltage regulator module.
Arguments
• arg1 = number
Detailed
Description
System performance may be degraded or the system may fail to operate.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
276