Reference Guide

Trap/EventID 2241
LCD Message CPU bus parity error detected. Power cycle system
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
CPU0703
Message CPU bus initialization error detected.
Detailed
Description
System event log and OS logs may indicate that the exception is external to the
processor.
Recommended
Response
Action
1) Check system and operating system logs for exceptions. If no exceptions are
found continue. 2) Turn system off and remove input power for one minute. Re-
apply input power and turn system on. 3) Make sure the processor is seated
correctly. 4) If the issue still persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category System Health
Subcategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU bus initialization error detected. Power cycle system
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
CPU0704
Message CPU arg1 machine check error detected.
Arguments
arg1 = number
Detailed
Description
System event log and OS logs may indicate that the exception is external to the
processor.
274