Reference Guide
Recommended
Response
Action
Review logs for fan failures, replace failed fans. If no fan failures are detected,
check inlet temperature (if available) and reinstall processor heatsink.
Category System Health
Subcategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> has a thermal trip. Check CPU heat sink
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
5604
Server
Administrator
Trap ID
5604
CPU0002
Message CPU arg1 has failed the built-in self-test (BIST).
Arguments
• arg1 = number
Detailed
Description
None
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is inserted correctly,if the
processor is removable. 3) If the issue still persists, contact technical support. Refer
to the product documentation to choose a convenient contact method.
Category System Health
Subcategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
263