Reference Guide
Server
Administrator
Trap ID
Not Applicable
CBL0006
Message Unsupported backplane arg1 configuration: Multiple RAID controllers cannot be
connected to the same backplane.
Arguments
• arg1 = bay ID
Detailed
Description
Each server model only supports a certain set of backplane configurations. For
unified backplanes or split mode capable backplanes that are in unified mode,
multiple controllers cannot be connected to the same backplane. In unified
backplane situations any controller besides the first will not be operational.
Recommended
Response
Action
Make sure that only one RAID controller is connected to the backplane. If the issue
persists, contact your service provider.
Category System Health
Subcategory CBL = Cable
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
CBL0007
Message Backplane arg1 arg2 cable and backplane arg3 arg4 cable are swapped.
Arguments
• arg1 = bay ID
• arg2 = cable name
• arg3 = bay ID
• arg4 = cable name
Detailed
Description
The backplane cables identified in the message need to be connected to the
correct backplane bays.
259