Reference Guide

8
CBL Event Messages
CBL0001
Message Backplane arg1 power cable disconnected.
Arguments
arg1 = bay ID
Detailed
Description
A backplane signal cable was detected, but the accompanying power cable was
not present.
Recommended
Response
Action
Reconnect or replace the power cable. If the issue persists, contact your service
provider.
Category System Health
Subcategory CBL = Cable
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
CBL0002
Message Backplane arg1 signal cable disconnected.
Arguments
arg1 = bay ID
Detailed
Description
A backplane power cable was detected, but the accompanying signal cable was
not present.
Recommended
Response
Action
Reconnect or replace the signal cable for the backplane identified in the message.
If the issue persists, contact your service provider.
Category System Health
256