Reference Guide
Recommended
Response
Action
Change the configuration of one or more attributes and then create a
configuration job.
Category Configuration
Subcategory BIOS = BIOS Management
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BIOS009
Message Lifecycle Controller is currently in use.
Detailed
Description
Lifecycle Controller cannot gain access to internal storage because of use by
another application or operation.
Recommended
Response
Action
Wait for the current Lifecycle Controller operation to complete. Verify that the
system is 1) Not currently in Lifecycle Controller Unified Server Configurator utility
2) Waiting for user intervention at F1/F2 POST error 3) Not in any of the device or
controller Option ROMs and retry the operation.
Category Configuration
Subcategory BIOS = BIOS Management
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
BIOS010
Message Lifecycle Controller is not enabled, cannot create Configuration job.
232