Reference Guide

Server
Administrator
Trap ID
5154
VLT405
Message The arg1 sensor has failed with a value of arg2 Volts.
Arguments
arg1 = sensor name
arg2 = voltage
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can
cause system performance issues and degradation in the moitoring capability of
the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
processor module and inspect processor socket, and replace if required. If the
issue persists, contact your service provider.
Category System Health
Subcategory VLT = Voltage
Severity Severity 1 (Critical)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None