Reference Guide

Server
Administrator
Trap ID
Not Applicable
VLT402
Message The arg1 sensor has returned to a normal state with a value of arg2 Volts.
Arguments
arg1 = sensor name
arg2 = voltage
Detailed
Description
The voltage sensor identified in the message has returned to a normal state.
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory VLT = Voltage
Severity Severity 3 (Informational)
LCD Message No LCD message display defined.
Initial Default SNMP Alert;OS Log;None
Server
Administrator
Event ID
5152
Server
Administrator
Trap ID
5152
VLT403
Message The arg1 sensor state has changed to a warning state with a value of arg2 Volts.
Arguments
arg1 = sensor name
arg2 = voltage
Detailed
Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the
preset warning threshold. This condition can cause system performance issues and
degradation in the moitoring capability of the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
board. 3) If the sensor identified is a processor voltage sensor, remove the
2262