Trap ID
Not Applicable
VLT0305
Message CPU arg1 arg2 voltage is within range.
Arguments
• arg1 = number
• arg2 = name
Detailed
Description
None
Recommended
Response
Action
No response action is required.
Category System Health
Subcategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID 2171
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT400
Message The arg1 sensor has failed with a value arg2 Volts.
Arguments
• arg1 = sensor name
• arg2 = voltage
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can
cause system performance issues and degradation in the moitoring capability of
the system.
Recommended
Response
Action
Do one of the following to resolve the issue: 1) Verify the Embedded System
Management (ESM) Log for any sensor related faults. If there is a failed sensor,
replace the system board. 2) Re-configure the system to a minimum configuration,
and verify if the sensor displays a normal value, otherwise replace the system
2260