Reference Guide

Server
Administrator
Trap ID
Not Applicable
VLT0302
Message CPU arg1 arg2 voltage is greater than the upper warning threshold.
Arguments
arg1 = number
arg2 = name
Detailed
Description
High voltages may be the result of problem with the voltage regulator or a problem
with the processor. Elevated voltages may result in damage to the processor or
other electronic components inside the system.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
Subcategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT0303
Message CPU arg1 arg2 voltage is greater than the upper critical threshold.
Arguments
arg1 = number
arg2 = name
Detailed
Description
High voltages may be the result of problem with the voltage regulator or a problem
with the processor. Elevated voltages may result in damage to the processor or
other system electrical components. The system may power down.
2258