Reference Guide

Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
Subcategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
Server
Administrator
Trap ID
Not Applicable
VLT0301
Message CPU arg1 arg2 voltage is less than the lower critical threshold.
Arguments
arg1 = number
arg2 = name
Detailed
Description
Low voltages may be the result of a problem with the voltage regulator or a
problem with the processor. When the critical threshold is crossed, the processor
will fail to operate. The system may power down.
Recommended
Response
Action
1) Turn system off and remove input power for one minute. Re-apply input power
and turn system on. 2) Make sure the processor is seated correctly. 3) If the issue
still persists, contact technical support. Refer to the product documentation to
choose a convenient contact method.
Category System Health
Subcategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message CPU <number> <name> voltage is outside of range. Reseat CPU
Initial Default IPMI Alert;LC Log
Server
Administrator
Event ID
Not Applicable
2257